Ningbo Leadkin Instrument Complete Sets of Equipment Co., Ltd.

Experts and innovators to solve the thermal control system

Manufacturer from China
Verified Supplier
4 Years
Home / Products / Mineral Insulated Thermocouple Cable /

Accurate Temperature Measurement Thermocouple Cable For High Temperature Measurement In Various Industries

Contact Now
Ningbo Leadkin Instrument Complete Sets of Equipment Co., Ltd.
Visit Website
Province/State:zhejiang
Country/Region:china
Contact Person:MsAmy Jiang
Contact Now

Accurate Temperature Measurement Thermocouple Cable For High Temperature Measurement In Various Industries

Ask Latest Price
Video Channel
Brand Name :LEADKIN
Model Number :LK-K
Certification :ISO9001, IATF16949, CE
Place of Origin :NINGBO CHINA
MOQ :50M
Price :negotiation
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :1,000,000M/year
Delivery Time :2-7 working days
Packaging Details :70*70*8cm Carton
Core :2,3,4,6
Insulation :MgO
Warranty :1 Year
Temperature Range :200℃-1000℃
Accuracy :Class I、II、III
Outside Dia :0.5-12.7mm
Package :Carton. Pallet
Function :temperature test
Cable Length :1-5m or Customized
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Quick Details:

Type: K/N/E/J/T/S/R/B

Place of Origin: Zhejiang, China (Mainland)

Accuracy: I-0.4%t, II-0.75%t, III-1.5%t

Core number: 2,3,4,6

Inorganic mineral insulating lead material: Ni, Cu

Insulator: 99.6% high purity MgO

Certificate:ISO9001, IATF16949, CE

Application: connecting with thermocouple and instrument machine

Sheath material: 0Cr18Ni10Ti, SS304S,SS316L,SS316, Cu

Sheath Dia(mm): φ3.0, φ4.0, φ6.0, φ8.0

Type for Sheath Wire Type K:

Product Name Code Type Shaeth Material Outside Dia. Temperature
NiCr-NiSi /NiCr-NiAl KK K SS304 SS316 0.5-1.0 400
1.5-3.2 600
4.0-8.0 800
SS310 Inconel600 0.5-1.0 500
1.5-3.2 800
4.0-6.4 900
8.0-12.7 1000
NiCrSi-NiSi NK N SS304 SS316 0.5-1.0 400
1.5-3.2 600
4.0-8.0 800
SS310 Inconel600 0.5-1.0 500
1.5-3.2 800
4.0-6.4 900
8.0-12.7 1000
NiCr-Konstantan EK E SS304 SS316 0.5-1.0 400
1.5-3.2 600
4.0-8.0 800
Fe-Konstantan JK J SS304 SS316 0.5-1.0 400
1.5-3.2 600
4.0-8.0 800
Cu-Konstantan TK T SS304 SS316 0.5-1.0 400
1.5-3.2 600
4.0-8.0 800
RhPt10-Ph SK S Inconel600 6.0-12.7 1100

Different temperature measuring media and service conditions have an impact on the service life and temperature range of armored thermocouples, the data in the table is only recommended data.

Accuracy for Sheath Wire Type K

Type Class I Class II
Accuracy Temp.Range Accuracy Temp.Range
K ±1.5℃ -40~375℃ ±2.5℃ -40~375℃
±0.4% 375℃-1000℃ ±0.75% 375℃-1000℃
N ±1.5℃ -40~375℃ ±2.5℃ -40~375℃
±0.4% 375℃-1000℃ ±0.75% 375℃-1000℃
E ±1.5℃ -40~375℃ ±2.5℃ -40~375℃
±0.4% 375℃-800℃ ±0.75% 375℃-800℃
J ±1.5℃ -40~375℃ ±2.5℃ -40~375℃
±0.4% 375℃-800℃ ±0.75% 375℃-800℃
T ±0.5℃ -40~125℃ ±1.0℃ -40~125℃
±0.4% 125℃-350℃ ±0.75% 125℃-350℃
S 0-1100℃ ±1.0℃ 0-1100℃ ±1.5℃

About this product:

Configuration:

Thermocouple cables can come in various configurations, including single pair (one thermocouple) or multi-pair (multiple thermocouples in one cable).

Shielding:

Some thermocouple cables are shielded to minimize electromagnetic interference (EMI), which can affect the accuracy of temperature readings, especially in industrial environments.

Color Coding:

Thermocouple cables are often color-coded to indicate the type of thermocouple they are compatible with. For example, Type K thermocouples typically use yellow insulation.

Applications:

Thermocouple cables are used in a wide range of applications, including HVAC systems, manufacturing processes, food processing, and scientific research where precise temperature monitoring is critical.

Important Considerations:

Calibration: Ensure that the thermocouple and the associated cable are properly calibrated to maintain measurement accuracy.

Length: The length of the thermocouple cable can affect accuracy. Longer cables may introduce voltage drops, so it's important to use appropriate lengths based on the application.

Environment: Consider the environmental conditions (e.g., exposure to chemicals, humidity, and temperature extremes) when selecting the appropriate thermocouple cable.

Choosing the right thermocouple cable is vital for ensuring accurate temperature measurements and maintaining the reliability of your temperature monitoring systems.

Types of MI Cables for Thermocouples:

Type K MI Cable

Composition: Uses Chromel (nickel-chromium alloy) and Alumel (nickel-aluminum alloy).

Temperature Range: -200°C to +1260°C (-328°F to +2300°F).

Applications: Widely used in industrial applications, food processing, and general-purpose temperature measurement.

Type N MI Cable

Composition: Comprises Nicrosil (nickel-chromium-silicon alloy) and Nisil (nickel-silicon alloy).

Temperature Range: -200°C to +1300°C (-328°F to +2372°F).

Applications: Suitable for high-temperature measurements and environments prone to oxidation.

Type E MI Cable

Composition: Consists of Chromel and Constantan (copper-nickel alloy).

Temperature Range: -200°C to +900°C (-328°F to +1652°F).

Applications: Ideal for cryogenic applications and environments with high magnetic fields.

Type T MI Cable

Composition: Made of Copper and Constantan.

Temperature Range: -200°C to +350°C (-328°F to +662°F).

Applications: Best suited for low-temperature applications, including cryogenic environments.

Type J MI Cable

Composition: Composed of Iron and Constantan.

Temperature Range: -40°C to +750°C (-40°F to +1382°F).

Applications: Limited usage in vacuum or inert atmospheres due to potential oxidation of iron.

Type S MI Cable

Composition: Made from Platinum and Rhodium (typically 10% Rhodium).

Temperature Range: 0°C to +1600°C (32°F to +2912°F).

Applications: High-precision applications, often used in laboratories and industrial processes requiring high-temperature measurement.

Applications :

  • Solid waste incinerators
  • Sintering powdered metals
  • Firing ceramic materials
  • Gas or oil fired furnaces
  • Fuel fired heat exchangers
  • Box furnaces
  • Nuclear or hydrocarbon based energy plants
  • And many more...

Product Pictures:

Accurate Temperature Measurement Thermocouple Cable For High Temperature Measurement In Various Industries

Company Information:

A. Main Products

Accurate Temperature Measurement Thermocouple Cable For High Temperature Measurement In Various Industries

Accurate Temperature Measurement Thermocouple Cable For High Temperature Measurement In Various Industries

B. Package

We add heat shrink tubing and plastic film to make sure high insulated resistance.

Except marking notes, we also have pass card and test report for every coil cable.

Accurate Temperature Measurement Thermocouple Cable For High Temperature Measurement In Various Industries

C. Mi cable Production line

We have high - quality professional products, as well as advanced product lines and equipments. All of the products comply with international quality standards and are greatly appreciated in a variety of different markets throughout the world.Along the increasing market demands, we continuously satisfy customers by updating products to improve prouduction systems, improve quality.

Order Notice:

1. Accurate quotation.

2. Confirm the price, trade term, lead time, payment term etc.

3. LEADKIN sales send the Proforma Invoice with LEADKIN seal.

4. Customer arranges the payment for deposit and sends us bank slip.

5. Middle Production-send photos to show the production line which you can see your products in . Confirm the estimated delivery time again.

6. End Production-Mass production products photos.

7. Clients make payment for balance and LEADKIN ships the goods. Inform the tracking number and check the status for clients.

8. The order is finished perfectly when you receive the goods and get satisfied with them .

9. Feedback to LEADKIN about Quality , Service, Market Feedback & Suggestion. And we will do better .


Inquiry Cart 0